Customization: | Available |
---|---|
Application: | Power, Instrument, Rectifier |
Phase: | Three |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
10kV/20kV/35kV 0.4 Oil-Immersed Three-Phase Transformer
Introducing the 20kV Oil-Immersed Transformer, an epitome of electrical innovation where insulating oil serves as the critical insulating medium. This marvel of engineering comprises an iron core, coil, voltage regulating switch, oil tank, and more, proficiently altering voltage and ensuring the seamless transmission of alternating current energy. Noteworthy for its compact size, budget-friendly pricing, and robust weather resistance, this transformer is indispensable across power systems, industrial and mining enterprises, transportation, postal and telecommunications departments, as well as esteemed scientific research institutions.
nominal
capacity
|
high
voltage side
|
High voltage
tap range
|
low
voltage side
|
Connection
group labeling
|
No-
load loss
|
Load Loss |
No-load
current
|
Short Circuit
Impedance
|
30KVA |
11KV
10.5KV
10KV 6.3KV 6KV |
±5
±2×2.5%
|
0.4KV
0.69KV
|
Dyn11
Yyn0
|
100W | 630/600W | 2.3% | 4% |
50KVA | 130W | 910/870W | 2.0% | 4% | ||||
63KVA | 150W | 1090/1040W | 1.9% | 4% | ||||
80KVA | 180W | 1310/1250W | 1.9% | 4% | ||||
100KVA | 200W | 1580/1500W | 1.8% | 4% | ||||
125KVA | 240W | 1890/1800W | 1.7% | 4% | ||||
160KVA | 280W | 2310/2200W | 1.6% | 4% | ||||
200KVA | 340W | 2730/2600W | 1.5% | 4% | ||||
250KVA | 400W | 3200/3050W | 1.4% | 4% | ||||
315KVA | 480W | 3830/3650W | 1.4% | 4% | ||||
400KVA | 570W | 4520/4300W | 1.3% | 4% | ||||
500KVA | 680W | 5410/5150W | 1.2% | 4% | ||||
630KVA | 810W | 6200W | 1.1% | 4.5% | ||||
800KVA | 960W | 7500W | 1.0% | 4.5% | ||||
1000KVA | 1150W | 10300W | 1.0% | 4.5% | ||||
1250KVA | 1360W | 12000W | 0.9% | 4.5% | ||||
1600KVA | 1640W | 14500W | 0.8% | 4.5% | ||||
2000KVA | 1960W | 19800W | 0.8% | 5% | ||||
2500KVA | 2310W | 23000W | 0.7% | 5% |
Installation Instructions:
1. Installation Form:
Explore versatile installation options for the 20kV Oil-Immersed Transformers, including pole-mounted setups, outdoor installations, and indoor transformer placements.
Outdoor installations require a sturdy reinforced concrete foundation. For indoor setups, ensure the transformer aligns perfectly with the cabinet front, maintaining a seamless fit against the distribution panel.
2. Installation Steps:
For optimal placement, leverage the specially designed force points of the transformer, implementing anti-slip measures for stability.
During transport and installation, maintain the transformer's body inclination within safe limits-no more than 15° along the long axis and 10° along the short axis.
Mind the precision of gaps between components during installation to avoid excessive tightness or looseness.
Select suitable insulation disks based on actual conditions when installing terminals, ensuring accurate wiring.
3. Attachment Installation:
Ensure compliance with relevant standards and manufacturer protocols when installing accessories like gas relays, pressure relief devices, moisture absorbers, and sleeves.
Certificates: