10kv/20kv/35kv 0.4 Oil-Immersed Three-Phase Transformer
Our 20kV oil-immersed transformer stands as a paragon of electrical engineering excellence. Meticulously crafted, it utilizes premium insulating oil as its medium, encompassing components like the iron core, coil, voltage-regulating switch, and oil tank. This prodigious equipment is pivotal for voltage modulation and alternating current energy transmission. Distinguished by its compact stature, cost-effectiveness, and robust weather resilience, it serves a broad spectrum of applications across power systems, industrial sectors, mining enterprises, transportation networks, telecommunication departments, and scientific research institutions.
nominal
capacity
|
high
voltage side
|
High voltage
tap range
|
low
voltage side
|
Connection
group labeling
|
No-
load loss
|
Load Loss |
No-load
current
|
Short Circuit
Impedance
|
30KVA |
11KV
10.5KV
10KV 6.3KV 6KV |
±5
±2×2.5%
|
0.4KV
0.69KV
|
Dyn11
Yyn0
|
100W | 630/600W | 2.3% | 4% |
50KVA | 130W | 910/870W | 2.0% | 4% | ||||
63KVA | 150W | 1090/1040W | 1.9% | 4% | ||||
80KVA | 180W | 1310/1250W | 1.9% | 4% | ||||
100KVA | 200W | 1580/1500W | 1.8% | 4% | ||||
125KVA | 240W | 1890/1800W | 1.7% | 4% | ||||
160KVA | 280W | 2310/2200W | 1.6% | 4% | ||||
200KVA | 340W | 2730/2600W | 1.5% | 4% | ||||
250KVA | 400W | 3200/3050W | 1.4% | 4% | ||||
315KVA | 480W | 3830/3650W | 1.4% | 4% | ||||
400KVA | 570W | 4520/4300W | 1.3% | 4% | ||||
500KVA | 680W | 5410/5150W | 1.2% | 4% | ||||
630KVA | 810W | 6200W | 1.1% | 4.5% | ||||
800KVA | 960W | 7500W | 1.0% | 4.5% | ||||
1000KVA | 1150W | 10300W | 1.0% | 4.5% | ||||
1250KVA | 1360W | 12000W | 0.9% | 4.5% | ||||
1600KVA | 1640W | 14500W | 0.8% | 4.5% | ||||
2000KVA | 1960W | 19800W | 0.8% | 5% | ||||
2500KVA | 2310W | 23000W | 0.7% | 5% |
Installation Instructions:
1. Installation form:
The 20kV oil-immersed transformers can be installed in various forms such as pole-mounted setups, outdoor installations, and indoor transformer facilities, tailored to your specific environmental needs.
For outdoor installations, anchoring on a reinforced concrete foundation is imperative; whereas indoor installations necessitate ensuring the transformer aligns flush with the cabinet front and securely fits against the distribution panel without gaps.
2. Installation steps:
Upon positioning the transformer, leverage the design-specific force points and employ meticulous anti-slip measures.
During transit and installation, maintain the transformer's inclination within prescribed limits (not exceeding 15° in the long axis and 10° in the short axis) to ensure optimal performance.
Exercise caution to ensure each component is neither overly tight nor excessively loose to maintain structural integrity during installation.
For terminal installations, select appropriate insulation disks that align with the contextual needs and execute precise wiring.
3. Attachment installation:
For accessory installations such as gas relays, pressure relief devices, moisture absorbers, and sleeves, adhere rigorously to relevant standards and manufacturer specifications for flawless functionality.