Customization: | Available |
---|---|
Application: | Power, Instrument, Rectifier |
Phase: | Three |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
10kv/20kv/35kv 0.4 Oil-Immersed Three-Phase Transformer
A 20kV oil immersed transformer is an indispensable component in modern electrical systems. Utilizing high-quality insulating oil as its medium, this sophisticated equipment encompasses an iron core, coils, a voltage regulating switch, and a robust oil tank. Designed to efficiently alter voltage levels and transmit alternating current, this transformer is celebrated for its compact design, affordability, and exceptional resistance to diverse weather conditions. It finds extensive applications across power systems, industrial and mining sectors, transportation networks, postal and telecommunications departments, as well as research institutions.
nominal
capacity
|
high
voltage side
|
High voltage
tap range
|
low
voltage side
|
Connection
group labeling
|
No-
load loss
|
Load Loss |
No-load
current
|
Short Circuit
Impedance
|
30KVA |
11KV
10.5KV
10KV 6.3KV 6KV |
±5
±2×2.5%
|
0.4KV
0.69KV
|
Dyn11
Yyn0
|
100W | 630/600W | 2.3% | 4% |
50KVA | 130W | 910/870W | 2.0% | 4% | ||||
63KVA | 150W | 1090/1040W | 1.9% | 4% | ||||
80KVA | 180W | 1310/1250W | 1.9% | 4% | ||||
100KVA | 200W | 1580/1500W | 1.8% | 4% | ||||
125KVA | 240W | 1890/1800W | 1.7% | 4% | ||||
160KVA | 280W | 2310/2200W | 1.6% | 4% | ||||
200KVA | 340W | 2730/2600W | 1.5% | 4% | ||||
250KVA | 400W | 3200/3050W | 1.4% | 4% | ||||
315KVA | 480W | 3830/3650W | 1.4% | 4% | ||||
400KVA | 570W | 4520/4300W | 1.3% | 4% | ||||
500KVA | 680W | 5410/5150W | 1.2% | 4% | ||||
630KVA | 810W | 6200W | 1.1% | 4.5% | ||||
800KVA | 960W | 7500W | 1.0% | 4.5% | ||||
1000KVA | 1150W | 10300W | 1.0% | 4.5% | ||||
1250KVA | 1360W | 12000W | 0.9% | 4.5% | ||||
1600KVA | 1640W | 14500W | 0.8% | 4.5% | ||||
2000KVA | 1960W | 19800W | 0.8% | 5% | ||||
2500KVA | 2310W | 23000W | 0.7% | 5% |
Installation Instructions:
1. Installation form:
The installation forms for 20kV oil immersed transformers are versatile, encompassing pole-mounted setups, outdoor installations, and indoor transformer placements.
For outdoor installations, secure the transformer on a solid reinforced concrete foundation. Indoors, ensure the transformer is aligned flush with the cabinet front and firmly secured to the distribution panel, leaving no gaps.
2. Installation steps:
Upon positioning the transformer, utilize designated force points to stabilize it, implementing both anti-slip and safety measures.
During transport and installation, maintain the transformer's body's inclination within specified limits: no more than 15° along the long axis and 10° along the short axis.
While installing, ensure that the gaps between components are neither excessively tight nor overly loose to facilitate optimal performance.
Select appropriate insulation disks for terminal installations based on the actual environmental conditions and ensure correct wiring.
3. Attachment installation:
When fitting accessories like gas relays, pressure relief devices, moisture absorbers, and sleeves, adhere strictly to relevant standards and manufacturer guidelines to ensure complete compliance and safety.
Certificates: