No | Item | Unit | FZN25-12D /T630-20 Load break switch | FZN25-12D /T630-20KLoad breakswitch(Can opencut short circuitcurrent | FZN25-12D /T25-315 Load break switch (Load break switch Can open cut short circuit current) |
1 | Rated voltage | kV | 12 | 12 | |
2 | Rated frequency | Hz | 50 | 50 | |
3 | Rated short time withstand current(2s)(peak value) | A | 630 | 125 | |
4 | Rated short-circuit making current | kA | 2050 | - | |
5 | Rated breaking current | kA | 50 | 80 | |
6 | Rated resistive load dropout current | kA | - | 31.5 | |
7 | Rated closed loop dropout current | A | 630 | - | |
8 | Rated cable recharging dropout current | A | 10 | 10 | |
9 | Interrupting no-load transformer capacity | kVA | - | - | |
10 | Rated interrupting take over current | A | - | - | |
11 | Power frequency withstand voltage, between poles, to earth/isolating distance | kA | 42/48 | 42/48 | |
12 | Power frequency withstand voltage, between poles, to earth/isolating distance | kV | 75/85 | 75/85 | |
13 | Short time withstand current peak of earth switch | kA | 20/50 | 20/50 | |
14 | Power frequency with satand voltage between poles to earth/isolating distance | kV | 75/85 | 75/85 | |
15 | Power frequency withstand voltage of auxiliary loop | V | 2000 | 2000 | |
16 | Contact clearance of load break switch | mm | 8±1 | 9±1 | |
17 | Average opening speed of load break switch | m/s | 10±0.2 | 10±0.2 | |
18 | Average closing speed of load break switch | m/s | 0.6±0.2 | 07±0.2 | |
19 | Different period of three-phase break and close brake | ms | ≤2 | ≤2 | |
20 | Jump time of contact closing | ms | ≤5 | ≤5 | |
21 | Rated contact pressure | N | ≤650 | ≤650 | |
22 | Closing time difference of disconnecting switch and load break switch | ms | ≥10 | ≥10 | |
23 | Opening time difference of disconnecting switch and load break switch | - | ≥300 | ≥300 | |
24 | Opening time of triggering the imager | - | - | >0.045 | |
25 | Opening time of release | s | >0.04 | >0.04 | |
26 | Motorized opening time | s | ≥1 | 0.3 | |
27 | Opening time (motorized) of disconnecting switch | s | ≥2 | ≥2 | |
28 | Clearance of disconnecting switch and load break switch | m | >150 | >150 | |
29 | Disconnecting switch and load break switch linkage mechanical life | time | >5000 | >5000 | |
30 | Outline Dimension (L×W×H) | m | 980×434×892 | 985×518 (Contains the fuse)×892 | |