10kv/20kv/35kv 0.4 Oil-Immersed Three-Phase Transformer
The 20kV oil-immersed transformer is a vital piece of electrical equipment that ingeniously utilizes insulating oil as its medium. Featuring a sophisticated iron core, coil, voltage regulating switch, and oil tank, it seamlessly alters voltage levels and efficiently transmits alternating current energy. Its noteworthy attributes of compact design, affordability, and resilience against harsh weather make it an indispensable asset across various domains, including power systems, industrial and mining enterprises, transportation networks, telecommunications sectors, and scientific research facilities, ensuring optimal performance and reliability.
nominal
capacity
|
high
voltage side
|
High voltage
tap range
|
low
voltage side
|
Connection
group labeling
|
No-
load loss
|
Load Loss |
No-load
current
|
Short Circuit
Impedance
|
30KVA |
11KV
10.5KV
10KV 6.3KV 6KV |
±5
±2×2.5%
|
0.4KV
0.69KV
|
Dyn11
Yyn0
|
100W | 630/600W | 2.3% | 4% |
50KVA | 130W | 910/870W | 2.0% | 4% | ||||
63KVA | 150W | 1090/1040W | 1.9% | 4% | ||||
80KVA | 180W | 1310/1250W | 1.9% | 4% | ||||
100KVA | 200W | 1580/1500W | 1.8% | 4% | ||||
125KVA | 240W | 1890/1800W | 1.7% | 4% | ||||
160KVA | 280W | 2310/2200W | 1.6% | 4% | ||||
200KVA | 340W | 2730/2600W | 1.5% | 4% | ||||
250KVA | 400W | 3200/3050W | 1.4% | 4% | ||||
315KVA | 480W | 3830/3650W | 1.4% | 4% | ||||
400KVA | 570W | 4520/4300W | 1.3% | 4% | ||||
500KVA | 680W | 5410/5150W | 1.2% | 4% | ||||
630KVA | 810W | 6200W | 1.1% | 4.5% | ||||
800KVA | 960W | 7500W | 1.0% | 4.5% | ||||
1000KVA | 1150W | 10300W | 1.0% | 4.5% | ||||
1250KVA | 1360W | 12000W | 0.9% | 4.5% | ||||
1600KVA | 1640W | 14500W | 0.8% | 4.5% | ||||
2000KVA | 1960W | 19800W | 0.8% | 5% | ||||
2500KVA | 2310W | 23000W | 0.7% | 5% |
Installation Instructions:
1. Installation form:
The versatile installation options for the 20kV oil-immersed transformers include pole-mounted setups, outdoor installations, and indoor placements, catering to diverse application needs.
For optimal stability, outdoor installations require secure placement on a reinforced concrete foundation, whereas indoor installations demand precise alignment, ensuring the transformer aligns flush with the cabinet front, seamlessly integrating with the distribution panel without any gaps.
2. Installation steps:
Upon positioning the transformer, strategically designed force points should be employed, accompanied by anti-slip measures to ensure steadfast installation.
During transport and installation, it is crucial to maintain the transformer's body inclination within defined limits-maximum 15° along the long axis and 10° along the short axis-to prevent mishaps.
Careful attention must be given to the gaps between components during installation, striking a balance to avoid excessive tightness or looseness.
Appropriate insulation discs should be selected based on situational requirements for terminal installation to guarantee proper wiring connections.
3. Attachment installation:
Installation of critical accessories such as gas relays, pressure relief devices, moisture absorbers, and sleeves must adhere to relevant standards and manufacturer guidelines to ensure optimal performance and safety.