Introducing the Three-Phase Oil-Immersed Distribution Transformer, a pinnacle of power systems engineering designed to meet your energy distribution needs with unmatched efficiency.
Product Parameters: Comprehensive specifications tailored to optimize performance across various applications.
nominal
capacity
|
high
voltage side
|
High voltage
tap range
|
low
voltage side
|
Connection
group labeling
|
No-
load loss
|
Load Loss |
No-load
current
|
Short Circuit
Impedance
|
30KVA |
11KV
10.5KV
10KV
6.3KV
6KV
|
±5
±2×2.5%
|
0.4KV
0.69KV
|
Dyn11
Yyn0
|
100W |
630/600W |
2.3% |
4% |
50KVA |
130W |
910/870W |
2.0% |
4% |
63KVA |
150W |
1090/1040W |
1.9% |
4% |
80KVA |
180W |
1310/1250W |
1.9% |
4% |
100KVA |
200W |
1580/1500W |
1.8% |
4% |
125KVA |
240W |
1890/1800W |
1.7% |
4% |
160KVA |
280W |
2310/2200W |
1.6% |
4% |
200KVA |
340W |
2730/2600W |
1.5% |
4% |
250KVA |
400W |
3200/3050W |
1.4% |
4% |
315KVA |
480W |
3830/3650W |
1.4% |
4% |
400KVA |
570W |
4520/4300W |
1.3% |
4% |
500KVA |
680W |
5410/5150W |
1.2% |
4% |
630KVA |
810W |
6200W |
1.1% |
4.5% |
800KVA |
960W |
7500W |
1.0% |
4.5% |
1000KVA |
1150W |
10300W |
1.0% |
4.5% |
1250KVA |
1360W |
12000W |
0.9% |
4.5% |
1600KVA |
1640W |
14500W |
0.8% |
4.5% |
2000KVA |
1960W |
19800W |
0.8% |
5% |
2500KVA |
2310W |
23000W |
0.7% |
5% |
Oil-immersed Transformers Product Details: Dive deep into the exceptional specifics of our oil-immersed transformers, engineered for excellence.
Oil-immersed transformers stand as vital power equipment in energy systems, primarily facilitating voltage conversion and seamless power transmission. Crafted to address high current and substantial capacity demands, these transformers offer unparalleled stability and reliability in power systems.
Model Meaning: Decode the model specifications to understand the innovative technology encapsulated in each transformer.
Performance Characteristics: Discover the elite attributes that make our transformers a preferred choice for efficiency and reliability.
1. Winding structure: Expertly engineered to enhance shock distribution, minimize magnetic leakage, and maximize mechanical strength, ensuring robust short-circuit resistance.
The high-voltage winding features a multi-layer cylindrical design, providing continuous or connecting continuous structure. This enhances shock distribution of the winding, minimizes magnetic leakage, and offers substantial mechanical strength with strong short-circuit resistance.
2. Iron core design: Optimized using premium cold-rolled grain-oriented silicon steel sheets with a diagonal seam stacking methodology to significantly reduce both no-load loss and no-load current.
Our adoption of high-quality cold-rolled grain-oriented silicon steel sheets with a full diagonal seam stacking method ensures a remarkable reduction in no-load loss and minimizes no-load current.
3. Fastening and anti-loosening: Designed with self-locking anti-loosening nuts for vibration resilience during transport, ensuring all fasteners maintain integrity throughout extended operational periods.
The core and windings are secured with robust fastening measures. Key components, including the high and low voltage leads, are equipped with self-locking anti-loosening nuts. Our non-hanging center structure safeguards against transport-induced vibrations. All fasteners come with secure nuts, ensuring stability during long-term use.
4. Vacuum processing: The innovative vacuum drying of coils and cores, coupled with vacuum filtering and injection of transformer oil, decisively reduces moisture content within the transformer.
Coils and cores undergo vacuum drying, and the transformer oil is vacuum filtered and injected, significantly minimizing moisture ingress within the transformer.
5. Oil tank design: Features a corrugated sheet with breathing capability to adapt to oil volume changes from temperature variations, eliminating the need for an oil storage cabinet and reducing the transformer's height.
The oil tank incorporates corrugated sheets with a breathing function to adjust for oil volume changes due to temperature fluctuations, effectively eliminating the necessity for an oil storage cabinet and consequently lowering the transformer's height.
6. Other features: Boasting a sleek design, compact size, and minimal installation footprint, this product is the epitome of maintenance-free convenience.
Displaying a beautiful appearance and compact volume, these transformers require minimal installation space, making them the ideal maintenance-free solution for a variety of environments.
Widely deployed across power plants, substations, industrial and mining enterprises, as well as rural power grids, these transformers enhance power distribution systems effectively.
Environment and Requirements: Ensure optimal performance by adhering to environmental and operational guidelines.
Ambient temperature: Ideally maintained between -25°C and +40°C for peak efficiency. The ambient temperature is optimally required to be between -25°C and +40°C to ensure the transformer operates at peak performance.
Altitude limit: Maintained below 1000m to preserve operational efficiency and safety. The altitude should not exceed 1000m to maintain operational efficiency and ensure safe usage of the transformer.
Air humidity: Restricted to a maximum of 90% relative humidity at +25ºC for ideal transformer operation. Air humidity should not exceed 90% relative humidity at a temperature of +25ºC to maintain optimal operational conditions.
Installation place: Choose a location devoid of corrosive gases and significant dirt accumulation to protect transformer integrity. Select an installation area free from corrosive gases and noticeable dirt to ensure the longevity and optimal performance of the transformer.
Maintenance and upkeep: Essential practices to extend transformer life and maintain peak performance.
Regular inspection: Routine checks of oil levels and insulation strength are crucial; timely replacement of transformer oil is necessary if issues arise. Frequent inspection of oil levels and conducting oil insulation strength tests are essential. If any problems surface, it is imperative to replace the transformer oil promptly.
Stable operation: Maintain consistent transformer performance by preventing overloads and short circuits. Ensure stable operation by preventing overloads and short circuits to safeguard the transformer against abnormal conditions.
Safety attention: Prioritize ventilation and fire prevention during installation, adhering strictly to technical specifications. During installation, consider the environment's ventilation and fire prevention measures, ensuring they align with technical installation specifications.
Order process: Streamlined steps for effortless procurement and installation.
Factory Scene: Experience our cutting-edge manufacturing environment and witness the precision of our assembly processes.
Certificates: Assuring quality and compliance through recognized certifications.

FAQ: Navigate your inquiries with ease, finding answers to common questions.
1. Are you a trading company or manufacturer?
We are a distinguished factory with a decade's expertise in high and low voltage switchgears, substations, transformers, cable distribution boxes, and various electrical equipment, including vacuum circuit breakers and load break switches.
Our factory proudly stands as a premier supplier for the esteemed State Grid Corporation of China, reflecting our unwavering commitment to excellence.
2. Do you accept customized service?
We offer exceptional OEM/ODM services, allowing us to beautifully print your logo on our products. Our expert technical and quotation team is dedicated to crafting a project that perfectly matches your drawings and parameters, ensuring complete satisfaction.
3. What is your MOQ?
Our minimum order quantity (MOQ) is as low as just 1 piece, demonstrating our flexibility and customer-centric approach.
4. How long is your delivery lead time?
The delivery lead time is influenced by your specific product requirements and order quantity. Typically, we ensure delivery within a swift timeframe of 5 to 10 working days.
5. How do you solve quality problems?
To address quality concerns, please provide detailed photos of any issues. Our dedicated technical and quality testing teams will conduct a thorough analysis and provide a satisfactory solution within 2 business days.
6. What are your payment terms?
We require a 30% T/T payment in advance, with the remaining 70% due before shipment. We also accept payments via Western Union and L/C, offering flexible options to meet your needs.