10kv/20kv/35kv 0.4 Oil-Immersed Three-Phase Transformer
The 20kV oil-immersed transformer is a marvel of electrical equipment engineering. Utilizing insulating oil as the medium, it elegantly combines an iron core, coil, voltage regulating switch, and robust oil tank to transform voltages and seamlessly transmit alternating current energy. This impressive product stands out with its compact design, affordability, and remarkable resistance to harsh weather conditions. Its versatility makes it an indispensable asset across power systems, industrial and mining enterprises, as well as transportation, postal, telecommunications departments, and scientific research institutions.
nominal
capacity
|
high
voltage side
|
High voltage
tap range
|
low
voltage side
|
Connection
group labeling
|
No-
load loss
|
Load Loss |
No-load
current
|
Short Circuit
Impedance
|
30KVA |
11KV
10.5KV
10KV 6.3KV 6KV |
±5
±2×2.5%
|
0.4KV
0.69KV
|
Dyn11
Yyn0
|
100W | 630/600W | 2.3% | 4% |
50KVA | 130W | 910/870W | 2.0% | 4% | ||||
63KVA | 150W | 1090/1040W | 1.9% | 4% | ||||
80KVA | 180W | 1310/1250W | 1.9% | 4% | ||||
100KVA | 200W | 1580/1500W | 1.8% | 4% | ||||
125KVA | 240W | 1890/1800W | 1.7% | 4% | ||||
160KVA | 280W | 2310/2200W | 1.6% | 4% | ||||
200KVA | 340W | 2730/2600W | 1.5% | 4% | ||||
250KVA | 400W | 3200/3050W | 1.4% | 4% | ||||
315KVA | 480W | 3830/3650W | 1.4% | 4% | ||||
400KVA | 570W | 4520/4300W | 1.3% | 4% | ||||
500KVA | 680W | 5410/5150W | 1.2% | 4% | ||||
630KVA | 810W | 6200W | 1.1% | 4.5% | ||||
800KVA | 960W | 7500W | 1.0% | 4.5% | ||||
1000KVA | 1150W | 10300W | 1.0% | 4.5% | ||||
1250KVA | 1360W | 12000W | 0.9% | 4.5% | ||||
1600KVA | 1640W | 14500W | 0.8% | 4.5% | ||||
2000KVA | 1960W | 19800W | 0.8% | 5% | ||||
2500KVA | 2310W | 23000W | 0.7% | 5% |
Installation Instructions:
1. Installation form:
The versatile installation forms for 20kV oil-immersed transformers include pole-mounted setups, outdoor installations, and indoor transformer placements.
For outdoor installations, securing the unit on a reinforced concrete foundation is essential. Indoors, it must align flush with the cabinet's front, ensuring a snug fit against the distribution panel without any gaps for optimal performance.
2. Installation steps:
During positioning, ensure the use of specifically designed force points, incorporating anti-slip measures to hold the transformer securely in place.
It's crucial to control the transformer's body inclination during transportation and installation. The long axis should not exceed a 15° tilt, while the short axis remains within a 10° range.
Throughout installation, maintain vigilance over part alignment, ensuring no excessive tightness or looseness, which could compromise functionality.
Select the appropriate insulation disks and ensure correct wiring when installing terminals, adapting to real-time conditions.
3. Attachment installation:
When attaching accessories like gas relays, pressure relief devices, moisture absorbers, and sleeves, adherence to relevant standards and manufacturer guidelines is paramount.
Certificates: