Customization: | Available |
---|---|
Application: | Power, Instrument, Rectifier |
Phase: | Three |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Unleash the power of transformation with our 10kv/20kv/35kv 0.4 Oil-Immersed Three-Phase Transformer, designed to meet your energy needs with precision and efficiency.
Introducing our 20kV oil-immersed transformer, an essential component in the realm of electrical equipment. This sophisticated device utilizes insulating oil as its medium, encompassing an iron core, winding coils, a voltage regulating switch, and a resilient oil tank. It masterfully alters voltage levels and facilitates the seamless transmission of alternating current, ensuring the flow of energy remains unimpeded. Boasting a compact design, cost-effectiveness, and exceptional weather resilience, this transformer is indispensable across power systems, industrial plants, mining operations, transportation networks, postal and telecommunications sectors, as well as within scientific research institutions.
nominal
capacity
|
high
voltage side
|
High voltage
tap range
|
low
voltage side
|
Connection
group labeling
|
No-
load loss
|
Load Loss |
No-load
current
|
Short Circuit
Impedance
|
30KVA |
11KV
10.5KV
10KV 6.3KV 6KV |
±5
±2×2.5%
|
0.4KV
0.69KV
|
Dyn11
Yyn0
|
100W | 630/600W | 2.3% | 4% |
50KVA | 130W | 910/870W | 2.0% | 4% | ||||
63KVA | 150W | 1090/1040W | 1.9% | 4% | ||||
80KVA | 180W | 1310/1250W | 1.9% | 4% | ||||
100KVA | 200W | 1580/1500W | 1.8% | 4% | ||||
125KVA | 240W | 1890/1800W | 1.7% | 4% | ||||
160KVA | 280W | 2310/2200W | 1.6% | 4% | ||||
200KVA | 340W | 2730/2600W | 1.5% | 4% | ||||
250KVA | 400W | 3200/3050W | 1.4% | 4% | ||||
315KVA | 480W | 3830/3650W | 1.4% | 4% | ||||
400KVA | 570W | 4520/4300W | 1.3% | 4% | ||||
500KVA | 680W | 5410/5150W | 1.2% | 4% | ||||
630KVA | 810W | 6200W | 1.1% | 4.5% | ||||
800KVA | 960W | 7500W | 1.0% | 4.5% | ||||
1000KVA | 1150W | 10300W | 1.0% | 4.5% | ||||
1250KVA | 1360W | 12000W | 0.9% | 4.5% | ||||
1600KVA | 1640W | 14500W | 0.8% | 4.5% | ||||
2000KVA | 1960W | 19800W | 0.8% | 5% | ||||
2500KVA | 2310W | 23000W | 0.7% | 5% |
Installation Instructions:
1. Installation form:
Versatility in installation defines the 20kV oil-immersed transformers, suitable for pole-mounted setups, outdoor placements, and indoor installations, adapting seamlessly to any environment.
For outdoor installations, ensure the transformer is securely anchored on a reinforced concrete foundation. Indoor installations require precision, aligning the transformer body flush with the cabinet front and securely attached to the distribution panel, eliminating any gaps.
2. Installation steps:
During placement, employ designated force points to secure the transformer, implementing anti-slip measures to maintain stability and safety.
To ensure operational integrity, control the inclination of the transformer body within the specified range during transport and installation, not exceeding 15° along the long axis and 10° along the short axis.
Pay careful attention during installation to maintain optimal gaps between parts; avoid excessive tightness or looseness for optimal performance.
Select appropriate insulation disks for terminal installations, ensuring correct wiring to maintain operational efficiency and safety.
3. Attachment installation:
Adhere to relevant standards and manufacturer guidelines when installing accessories such as gas relays, pressure relief devices, moisture absorbers, and sleeves to guarantee optimal function and safety.
Certificates: