Customization: | Available |
---|---|
Application: | Power, Instrument, Rectifier |
Phase: | Three |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
10kV/20kV/35kV 0.4 Oil-Immersed Three-Phase Transformer
A 20kV oil-immersed transformer is a pivotal piece of electrical equipment, utilizing insulating oil as its core insulating medium. This sophisticated apparatus comprises an iron core, coil, voltage regulating switch, oil tank, and more. It serves the essential function of altering voltage and efficiently transmitting alternating current energy. Notable for its compact size, economical pricing, and robust weather resistance, this transformer finds extensive application across a broad spectrum of sectors including power systems, industrial and mining enterprises, transportation, postal and telecommunications departments, as well as esteemed scientific research institutions.
nominal
capacity
|
high
voltage side
|
High voltage
tap range
|
low
voltage side
|
Connection
group labeling
|
No-
load loss
|
Load Loss |
No-load
current
|
Short Circuit
Impedance
|
30KVA |
11KV
10.5KV
10KV 6.3KV 6KV |
±5
±2×2.5%
|
0.4KV
0.69KV
|
Dyn11
Yyn0
|
100W | 630/600W | 2.3% | 4% |
50KVA | 130W | 910/870W | 2.0% | 4% | ||||
63KVA | 150W | 1090/1040W | 1.9% | 4% | ||||
80KVA | 180W | 1310/1250W | 1.9% | 4% | ||||
100KVA | 200W | 1580/1500W | 1.8% | 4% | ||||
125KVA | 240W | 1890/1800W | 1.7% | 4% | ||||
160KVA | 280W | 2310/2200W | 1.6% | 4% | ||||
200KVA | 340W | 2730/2600W | 1.5% | 4% | ||||
250KVA | 400W | 3200/3050W | 1.4% | 4% | ||||
315KVA | 480W | 3830/3650W | 1.4% | 4% | ||||
400KVA | 570W | 4520/4300W | 1.3% | 4% | ||||
500KVA | 680W | 5410/5150W | 1.2% | 4% | ||||
630KVA | 810W | 6200W | 1.1% | 4.5% | ||||
800KVA | 960W | 7500W | 1.0% | 4.5% | ||||
1000KVA | 1150W | 10300W | 1.0% | 4.5% | ||||
1250KVA | 1360W | 12000W | 0.9% | 4.5% | ||||
1600KVA | 1640W | 14500W | 0.8% | 4.5% | ||||
2000KVA | 1960W | 19800W | 0.8% | 5% | ||||
2500KVA | 2310W | 23000W | 0.7% | 5% |
Installation Instructions:
1. Installation form:
The installation configurations for 20kV oil-immersed transformers are versatile, including pole-mounted setups, outdoor installations, and indoor transformer setups.
For outdoor installations, the transformer must be securely anchored on a reinforced concrete foundation. When installed indoors, it is crucial to ensure that the transformer body aligns perfectly with the cabinet front and is closely fitted to the distribution panel, eliminating any gaps.
2. Installation steps:
When positioning the transformer, it is imperative to utilize specially designed force points, along with implementing anti-slip measures for enhanced stability.
During transportation and installation, maintain the inclination of the transformer body within specified limits, not exceeding 15° along the long axis and 10° along the short axis.
During the installation process, it is essential to monitor the spacing between components to avoid excessive tightness or looseness.
When installing terminals, select appropriate insulation disks based on actual requirements and ensure correct wiring.
3. Attachment installation:
Installation of accessories such as gas relays, pressure relief devices, moisture absorbers, and sleeves must strictly adhere to relevant standards and manufacturer specifications.
Certificates: