Epoxy Resin Dry-Type Transformer
Discover safe, efficient, and ecologically conscious power solutions designed to save energy while preserving the environment.
parameter term |
parameter values |
rated voltage |
Various specifications available, such as 20KV, 10KV, 6KV, etc. |
Capacity range |
Various specifications are available, such as 500KVA, 630KVA, 800KVA, 1250KVA, etc. |
Cooling Method |
Natural air-cooled/forced air-cooled (according to specific models) |
Insulation material |
Epoxy resin or other high-performance insulating materials |
Protection class |
IPXX (according to the specific model, need to mark the specific level) |
Winding type |
Foil winding structure (low voltage) / "trapezoidal" segmented layer structure (high voltage) |
Core material |
High quality cold rolled grain oriented silicon steel sheet |
Technical Data Sheet for 6KV, 10KV Class 10 Dry Type Non-Excited Regulated Distribution Transformer |
nominal capacity |
Connection
group labeling
|
Voltage combination |
No-load
current
|
No-
load loss
|
Load Losses at Different Insulation Thermal Ratings |
Short Circuit
Impedance
|
B(100ºC) |
F(120ºC) |
H(145ºC) |
30KVA |
Yyn0
Dyn11 |
6-11±2×2.5%/0.4 |
2.1 |
190 |
670 |
710 |
760 |
4.0 |
50KVA |
2.1 |
270 |
940 |
1000 |
1070 |
4.0 |
80KVA |
1.6 |
370 |
1290 |
1380 |
1480 |
4.0 |
100KVA |
1.6 |
400 |
1480 |
1570 |
1690 |
4.0 |
125KVA |
1.5 |
470 |
1740 |
1850 |
1980 |
4.0 |
160KVA |
1.5 |
540 |
2000 |
2130 |
2280 |
4.0 |
200KVA |
1.3 |
620 |
2370 |
2530 |
2710 |
4.0 |
250KVA |
1.3 |
720 |
2590 |
2760 |
2960 |
4.0 |
315KVA |
1.1 |
880 |
3270 |
3470 |
3730 |
4.0 |
400KVA |
1.1 |
980 |
3750 |
3990 |
4280 |
4.0 |
500KVA |
1.1 |
1160 |
4590 |
4880 |
5230 |
4.0 |
630KVA |
0.9 |
1340 |
5530 |
5880 |
6290 |
4.0 |
630KVA |
0.9 |
1300 |
5610 |
5960 |
6400 |
6.0 |
800KVA |
0.9 |
1520 |
6550 |
6960 |
7460 |
6.0 |
1000KVA |
0.9 |
1770 |
7650 |
8130 |
8760 |
6.0 |
1250KVA |
0.9 |
2090 |
9100 |
9690 |
10370 |
6.0 |
1600KVA |
0.9 |
2450 |
11050 |
11730 |
12580 |
6.0 |
2000KVA |
0.9 |
3050 |
13600 |
14450 |
15560 |
6.0 |
2500KVA |
0.7 |
3600 |
16150 |
17170 |
18450 |
6.0 |
Anatomy of a Dry-Type Transformer
1. Iron Core: Constructed with silicon steel sheets, this core forms the magnetic circuit, guiding the magnetic flux with precision.
2. Winding: Split into high-voltage and low-voltage windings, these are precisely wound on the iron core to facilitate seamless energy transformation and distribution.
3. Insulating Cylinder: Strategically positioned between high and low voltage coils to enhance electrical insulation and ensure optimal operational safety.
4. Support Pads: Designed to uphold and stabilize the coils, maintaining their integrity and form.
5. Fasteners: Engineered to securely connect and fix each component of the transformer, providing exceptional anti-loosening capabilities.
Product Description:
Overview:
The 10kV dry-type transformer features a structure where core and windings remain free of insulating liquids, promoting safety, fire resistance, and environmental friendliness. Perfectly suited for industrial, commercial, and civil power systems.
Main Features:
Unparalleled Safety Performance: Boasts fireproof qualities and zero pollution, enabling operation at the load center to significantly enhance system security.
Exceptional Mechanical Strength: Designed to withstand strong short-circuits, minimize partial discharges, and ensure superior thermal stability for an extended lifespan.
Notable Energy-Saving Benefits: Characterized by low loss and minimal noise, this model achieves high operational efficiency, meeting contemporary energy conservation and environmental standards.
Outstanding Heat Dissipation Capability: Offers excellent thermal management with robust operational capacity; forced air cooling can further boost performance.
Resilient Environmental Adaptability: Impressive moisture resistance, adapting seamlessly to high humidity and adversarial environments.
Cost-Effective Maintenance: Features include eco-friendliness, flame retardance, explosion-proof design, and maintenance-free operation, all contributing to reduced maintenance expenses.
Compact and Lightweight Design: Facilitates easy transportation and installation, offering significant space savings.
After-Sales Service:
Comprehensive pre-sales consultation and tailored program design services are available to you.
Free repair or replacement services for product quality issues during the warranty period.
Lifetime technical support and after-sales service ensure absolute peace of mind for our customers.
Application Scenarios:
Substation Dockyard Urban Living Spaces
Electric Power Plants Harness Wind Power Railway Systems
Factory Environments:
![Low Loss 500kVA 20kv Distribution Transformer](//www.micstatic.com/athena/img/transparent.png)
Certifications:
Frequently Asked Questions:
1. Are you a trading company or manufacturer?
We are a seasoned factory with a decade of expertise in High and Low voltage switchgears, substations, transformers, cable distribution boxes, and a variety of electrical equipment, including vacuum circuit breakers and load break switches.
Our factory is proud to be a top supplier to the State Grid Corporation of China.
2. Do you offer customized services?
We provide comprehensive OEM/ODM services, allowing you to imprint your logo on our products. Our dedicated technical and quotation teams are ready to deliver a project tailored to your specifications and parameters.
3. What is your minimum order quantity (MOQ)?
Our minimum order quantity (MOQ) is set at a single piece, ensuring flexibility and ease for our valued customers.
4. How long is your delivery lead time?
The delivery lead time is contingent upon your specific product requirements and order quantity. Generally, you can expect delivery within a swift 5 to 10 working days.
5. How do you address quality issues?
To address any quality concerns, kindly provide detailed photographs of the issues encountered. Our dedicated technical and quality testing teams will conduct a thorough analysis and deliver a satisfactory resolution within just 2 days.
6. What are your payment terms?
We require a 30% T/T payment in advance, with the remaining 70% due prior to shipment. We also accommodate payments via West Union and L/C to ensure convenience.