Epoxy resin dry-type transformer
Discover unparalleled safety, efficiency, and eco-consciousness with our energy-saving power solutions.
parameter term |
parameter values |
rated voltage |
Various specifications available, such as 20KV, 10KV, 6KV, etc. |
Capacity range |
Various specifications are available, such as 500KVA, 630KVA, 800KVA, 1250KVA, etc. |
Cooling Method |
Natural air-cooled/forced air-cooled (according to specific models) |
Insulation material |
Epoxy resin or other high-performance insulating materials |
Protection class |
IPXX (according to the specific model, need to mark the specific level) |
Winding type |
Foil winding structure (low voltage) / "trapezoidal" segmented layer structure (high voltage) |
Core material |
High quality cold rolled grain oriented silicon steel sheet |
Technical Data Sheet for 6KV, 10KV Class 10 Dry Type Non-Excited Regulated Distribution Transformer |
nominal capacity |
Connection
group labeling
|
Voltage combination |
No-load
current
|
No-
load loss
|
Load Losses at Different Insulation Thermal Ratings |
Short Circuit
Impedance
|
B(100ºC) |
F(120ºC) |
H(145ºC) |
30KVA |
Yyn0
Dyn11 |
6-11±2×2.5%/0.4 |
2.1 |
190 |
670 |
710 |
760 |
4.0 |
50KVA |
2.1 |
270 |
940 |
1000 |
1070 |
4.0 |
80KVA |
1.6 |
370 |
1290 |
1380 |
1480 |
4.0 |
100KVA |
1.6 |
400 |
1480 |
1570 |
1690 |
4.0 |
125KVA |
1.5 |
470 |
1740 |
1850 |
1980 |
4.0 |
160KVA |
1.5 |
540 |
2000 |
2130 |
2280 |
4.0 |
200KVA |
1.3 |
620 |
2370 |
2530 |
2710 |
4.0 |
250KVA |
1.3 |
720 |
2590 |
2760 |
2960 |
4.0 |
315KVA |
1.1 |
880 |
3270 |
3470 |
3730 |
4.0 |
400KVA |
1.1 |
980 |
3750 |
3990 |
4280 |
4.0 |
500KVA |
1.1 |
1160 |
4590 |
4880 |
5230 |
4.0 |
630KVA |
0.9 |
1340 |
5530 |
5880 |
6290 |
4.0 |
630KVA |
0.9 |
1300 |
5610 |
5960 |
6400 |
6.0 |
800KVA |
0.9 |
1520 |
6550 |
6960 |
7460 |
6.0 |
1000KVA |
0.9 |
1770 |
7650 |
8130 |
8760 |
6.0 |
1250KVA |
0.9 |
2090 |
9100 |
9690 |
10370 |
6.0 |
1600KVA |
0.9 |
2450 |
11050 |
11730 |
12580 |
6.0 |
2000KVA |
0.9 |
3050 |
13600 |
14450 |
15560 |
6.0 |
2500KVA |
0.7 |
3600 |
16150 |
17170 |
18450 |
6.0 |
Fundamental Components of a Dry-Type Transformer
1. Iron core: Constructed from stacked silicon steel sheets, it forms the magnetic circuit, channeling the magnetic flux with precision.
2. Winding: Comprising high-voltage and low-voltage windings meticulously wound on the iron core to facilitate the seamless conversion and transmission of electrical energy.
3. Insulating cylinder: Strategically positioned between high and low voltage coils, enhancing electrical insulation and ensuring the transformer's safe operation.
4. Pads: Designed to support and stabilize the coils, maintaining their structural integrity and shape.
5. Fasteners: Essential for securely connecting and fixing each component of the transformer, featuring reliable anti-loosening properties.
Product Description:
Overview:
The 10kV dry-type transformer stands out with its core and windings free from insulating liquid, offering unmatched safety, fire resistance, and pollution-free operation. Perfectly suited for diverse power systems in industrial, commercial, and civil sectors.
Main features:
Unrivaled Safety Performance: Boasting fireproof and pollution-free qualities, it operates securely within the load center, elevating system safety.
Exceptional Mechanical Strength: With robust short-circuit resistance, minimal partial discharge, superior thermal stability, and an extended service life.
Exceptional Energy-Saving Benefits: Experience reduced energy loss, low noise, and high operational efficiency, aligning perfectly with modern energy-saving and eco-friendly standards.
Outstanding Heat Dissipation Performance: Excels in heat dissipation, boasting strong operational capacity; forced air-cooling can significantly enhance operational capability.
Robust Environmental Adaptability: Features excellent moisture-proof performance, adept at handling high humidity and other challenging environments.
Minimal Maintenance Costs: With eco-friendly, flame retardant, explosion-proof, and maintenance-free attributes, operational and maintenance expenses are minimized.
Compact and Lightweight Design: Facilitates easy transportation and installation while optimizing space utilization.
After-sales service:
Offering comprehensive pre-sales consulting along with expert program design services.
Enjoy complimentary repair or replacement services for any product quality issues arising during the warranty period.
Benefit from lifelong technical support and after-sales service, ensuring customers have absolute peace of mind.
Manufacturing Facilities:

Certificates:
FAQ:
1. Are you a trading company or manufacturer?
We are a renowned factory boasting 10 years of expertise in High and Low voltage switchgears, substations, transformers, cable distribution boxes, and a range of electrical equipment, including vacuum circuit breakers and load break switches.
Proudly recognized as an eminent supplier for the State Grid Corporation of China.
2. Do you offer customized services?
We provide comprehensive OEM/ODM services, including custom logo placement. Our skilled technical and quotation teams are equipped to deliver tailored projects in line with your specifications and parameters.
3. What is your Minimum Order Quantity (MOQ)?
Our Minimum Order Quantity, or MOQ, is just 1 piece, allowing you to experience our exceptional product quality without a large commitment.
4. How long is your delivery lead time?
Our delivery lead time varies based on your specific product requirements and order quantity. Typically, you can expect a swift turnaround of just 5 to 10 working days.
5. How do you address and resolve quality problems?
To resolve any quality issues, please provide detailed photographs of the problem areas. Our skilled technical and quality testing department will conduct a thorough analysis and deliver a satisfactory solution within 2 days.
6. What are your payment terms?
Our payment terms are flexible to suit your needs: 30% T/T in advance and 70% before shipment. We also accept West Union and L/C for your convenience.