Epoxy Resin Dry-Type Transformer
Safe, efficient, environmentally friendly, and energy-saving power solutions
parameter term |
parameter values |
rated voltage |
Various specifications available, such as 20KV, 10KV, 6KV, etc. |
Capacity range |
Various specifications are available, such as 500KVA, 630KVA, 800KVA, 1250KVA, etc. |
Cooling Method |
Natural air-cooled/forced air-cooled (according to specific models) |
Insulation material |
Epoxy resin or other high-performance insulating materials |
Protection class |
IPXX (according to the specific model, need to mark the specific level) |
Winding type |
Foil winding structure (low voltage) / "trapezoidal" segmented layer structure (high voltage) |
Core material |
High quality cold rolled grain oriented silicon steel sheet |
Technical Data Sheet for 6KV, 10KV Class 10 Dry Type Non-Excited Regulated Distribution Transformer |
nominal capacity |
Connection
group labeling
|
Voltage combination |
No-load
current
|
No-
load loss
|
Load Losses at Different Insulation Thermal Ratings |
Short Circuit
Impedance
|
B(100ºC) |
F(120ºC) |
H(145ºC) |
30KVA |
Yyn0
Dyn11 |
6-11±2×2.5%/0.4 |
2.1 |
190 |
670 |
710 |
760 |
4.0 |
50KVA |
2.1 |
270 |
940 |
1000 |
1070 |
4.0 |
80KVA |
1.6 |
370 |
1290 |
1380 |
1480 |
4.0 |
100KVA |
1.6 |
400 |
1480 |
1570 |
1690 |
4.0 |
125KVA |
1.5 |
470 |
1740 |
1850 |
1980 |
4.0 |
160KVA |
1.5 |
540 |
2000 |
2130 |
2280 |
4.0 |
200KVA |
1.3 |
620 |
2370 |
2530 |
2710 |
4.0 |
250KVA |
1.3 |
720 |
2590 |
2760 |
2960 |
4.0 |
315KVA |
1.1 |
880 |
3270 |
3470 |
3730 |
4.0 |
400KVA |
1.1 |
980 |
3750 |
3990 |
4280 |
4.0 |
500KVA |
1.1 |
1160 |
4590 |
4880 |
5230 |
4.0 |
630KVA |
0.9 |
1340 |
5530 |
5880 |
6290 |
4.0 |
630KVA |
0.9 |
1300 |
5610 |
5960 |
6400 |
6.0 |
800KVA |
0.9 |
1520 |
6550 |
6960 |
7460 |
6.0 |
1000KVA |
0.9 |
1770 |
7650 |
8130 |
8760 |
6.0 |
1250KVA |
0.9 |
2090 |
9100 |
9690 |
10370 |
6.0 |
1600KVA |
0.9 |
2450 |
11050 |
11730 |
12580 |
6.0 |
2000KVA |
0.9 |
3050 |
13600 |
14450 |
15560 |
6.0 |
2500KVA |
0.7 |
3600 |
16150 |
17170 |
18450 |
6.0 |
Fundamental Structure of Dry-Type Transformer
1. Iron Core: Composed of silicon steel sheets, forming the magnetic circuit of the transformer to guide magnetic flux efficiently.
2. Winding: Consists of both high-voltage and low-voltage windings, carefully wound on the iron core for effective energy conversion and transmission.
3. Insulating Cylinder: Positioned between high and low voltage coils, enhancing electrical insulation and ensuring the transformer's safe operation.
4. Pads: Designed to support and stabilize coils, maintaining their integrity and form.
5. Fasteners: Essential for securely connecting and fixing parts of the transformer, equipped with anti-loosening features.
Product Description:
Overview:
The 10kV dry-type transformer features a core and windings that are not immersed in any insulating liquid, offering safety, fire prevention, and pollution-free benefits. It is extensively utilized in industrial, commercial, and civil power systems.
Main Features:
Superior Safety Performance: Fireproof and pollution-free, this transformer can operate directly within load centers, enhancing system safety.
High Mechanical Strength: Exhibits robust short-circuit resistance, minimal partial discharge, excellent thermal stability, and a long service life.
Remarkable Energy-Saving Effect: Features low loss and noise, and high operating efficiency, meeting modern energy-saving and environmental protection standards.
Excellent Heat Dissipation Performance: Boasts superior heat dissipation and strong operational capability, with forced air cooling enhancing operational capacity.
Strong Environmental Adaptability: Exceptional moisture resistance, suitable for high humidity and other challenging environments.
Low Maintenance Cost: Environmentally friendly, flame retardant, explosion-proof, and maintenance-free, significantly reducing operational and maintenance expenses.
Compact and Lightweight Design: Facilitates easy transportation and installation, optimizing space.
After-Sales Service:
We offer comprehensive pre-sales consulting and program design services to meet your needs.
Free repair or replacement services are provided for faults due to product quality issues during the warranty period.
Enjoy lifelong technical support and after-sales service, ensuring a worry-free experience.
Application Scenarios:
Substation, Dockyard, City Life
Electric Power Plant Wind Power Railroads
Factory Scene:

Certificates:
FAQ:
1. Are you a trading company or manufacturer?
We are a professional factory with a decade of expertise in high and low voltage switchgears, substations, transformers, cable distribution boxes, and various electrical equipment such as vacuum circuit breakers, load break switches, and more.
Our factory proudly serves as an excellent supplier to the State Grid Corporation of China.
2. Do you accept customized service?
We provide OEM/ODM services, including logo printing on products. Our expert technical and quotation team is ready to deliver a project that meets your specifications, based on your drawings and parameters.
3. What is your Minimum Order Quantity (MOQ)?
Our MOQ is as convenient as it gets - just 1 piece.
4. How long is your delivery lead time?
The delivery lead time is tailored to meet your specific requirements and the quantity needed. On average, you can expect your order to be ready within a swift 5 to 10 working days.
5. How do you address quality concerns?
We kindly request that you provide detailed photographs of any quality issues encountered. Our dedicated technical and quality testing department will conduct a thorough analysis. Rest assured, we aim to deliver a satisfactory resolution within just 2 days.
6. What are your payment terms?
Our payment terms are straightforward: 30% T/T in advance, with the remaining 70% due before shipment. We also accommodate payments via West Union and L/C.