10kv/20kv/35kv 0.4 Oil-Immersed Three-Phase Transformer
Introducing the exceptional 20kV oil-immersed transformer-a pinnacle of electrical innovation that employs insulating oil as its superior medium. As an essential component comprising an iron core, coil, voltage regulating switch, and oil tank, this transformer masterfully alters voltage and transmits alternating current energy. Boasting compact size, affordability, and robust weather resistance, it stands as an indispensable asset across power systems, industrial and mining sectors, transportation, postal and telecommunications, and scientific research institutions.
nominal
capacity
|
high
voltage side
|
High voltage
tap range
|
low
voltage side
|
Connection
group labeling
|
No-
load loss
|
Load Loss |
No-load
current
|
Short Circuit
Impedance
|
30KVA |
11KV
10.5KV
10KV 6.3KV 6KV |
±5
±2×2.5%
|
0.4KV
0.69KV
|
Dyn11
Yyn0
|
100W | 630/600W | 2.3% | 4% |
50KVA | 130W | 910/870W | 2.0% | 4% | ||||
63KVA | 150W | 1090/1040W | 1.9% | 4% | ||||
80KVA | 180W | 1310/1250W | 1.9% | 4% | ||||
100KVA | 200W | 1580/1500W | 1.8% | 4% | ||||
125KVA | 240W | 1890/1800W | 1.7% | 4% | ||||
160KVA | 280W | 2310/2200W | 1.6% | 4% | ||||
200KVA | 340W | 2730/2600W | 1.5% | 4% | ||||
250KVA | 400W | 3200/3050W | 1.4% | 4% | ||||
315KVA | 480W | 3830/3650W | 1.4% | 4% | ||||
400KVA | 570W | 4520/4300W | 1.3% | 4% | ||||
500KVA | 680W | 5410/5150W | 1.2% | 4% | ||||
630KVA | 810W | 6200W | 1.1% | 4.5% | ||||
800KVA | 960W | 7500W | 1.0% | 4.5% | ||||
1000KVA | 1150W | 10300W | 1.0% | 4.5% | ||||
1250KVA | 1360W | 12000W | 0.9% | 4.5% | ||||
1600KVA | 1640W | 14500W | 0.8% | 4.5% | ||||
2000KVA | 1960W | 19800W | 0.8% | 5% | ||||
2500KVA | 2310W | 23000W | 0.7% | 5% |
Installation Instructions:
1. Installation form:
Explore varied installation methods for 20kV oil-immersed transformers, including pole-mounted setups, outdoor applications, and indoor installations, each offering unique advantages.
Ensure outdoor installations are securely anchored on reinforced concrete foundations; for indoor settings, the transformer should align seamlessly with the cabinet front, maintaining a snug fit against the distribution panel.
2. Installation steps:
Utilize specified force points during positioning, implementing anti-slip measures meticulously to ensure stability and security.
Maintain transformer body inclination within optimal limits during transport and installation (not exceeding 15° longitudinally and 10° laterally) to ensure precision and functionality.
During assembly, keenly monitor part gaps, avoiding excessive tightness or looseness for optimal operational efficacy.
Terminal installations necessitate careful selection of appropriate insulation disks, ensuring alignment with the actual setup and correct wiring.
3. Attachment installation:
Adhere to relevant standards and manufacturer guidelines when installing accessories like gas relays, pressure relief devices, moisture absorbers, and sleeves, for flawless integration.