Audited by an independent third-party inspection agency
10kv/20kv/35kv 0.4 Oil-Immersed Three-Phase Transformer
Introducing our superior 20kV oil-immersed transformer-an epitome of modern electrical equipment engineering. Utilizing high-grade insulating oil as the medium, this transformer is crafted with precision components including an iron core, coil, voltage regulating switch, and a robust oil tank. Designed to efficiently alter voltage and transmit alternating current energy, this product boasts a compact design, affordability, and exceptional weather resistance. Recognized for its versatile applications, it is a preferred choice across power systems, industrial and mining enterprises, transportation, postal and telecommunications sectors, and esteemed scientific research institutions.
nominal
capacity
|
high
voltage side
|
High voltage
tap range
|
low
voltage side
|
Connection
group labeling
|
No-
load loss
|
Load Loss |
No-load
current
|
Short Circuit
Impedance
|
30KVA |
11KV
10.5KV
10KV 6.3KV 6KV |
±5
±2×2.5%
|
0.4KV
0.69KV
|
Dyn11
Yyn0
|
100W | 630/600W | 2.3% | 4% |
50KVA | 130W | 910/870W | 2.0% | 4% | ||||
63KVA | 150W | 1090/1040W | 1.9% | 4% | ||||
80KVA | 180W | 1310/1250W | 1.9% | 4% | ||||
100KVA | 200W | 1580/1500W | 1.8% | 4% | ||||
125KVA | 240W | 1890/1800W | 1.7% | 4% | ||||
160KVA | 280W | 2310/2200W | 1.6% | 4% | ||||
200KVA | 340W | 2730/2600W | 1.5% | 4% | ||||
250KVA | 400W | 3200/3050W | 1.4% | 4% | ||||
315KVA | 480W | 3830/3650W | 1.4% | 4% | ||||
400KVA | 570W | 4520/4300W | 1.3% | 4% | ||||
500KVA | 680W | 5410/5150W | 1.2% | 4% | ||||
630KVA | 810W | 6200W | 1.1% | 4.5% | ||||
800KVA | 960W | 7500W | 1.0% | 4.5% | ||||
1000KVA | 1150W | 10300W | 1.0% | 4.5% | ||||
1250KVA | 1360W | 12000W | 0.9% | 4.5% | ||||
1600KVA | 1640W | 14500W | 0.8% | 4.5% | ||||
2000KVA | 1960W | 19800W | 0.8% | 5% | ||||
2500KVA | 2310W | 23000W | 0.7% | 5% |
Installation Instructions:
1. Installation form:
The versatile 20kV oil-immersed transformers can be installed in various forms, including pole-mounted, outdoor, or indoor settings, each suited to your specific needs.
For outdoor installations, ensure the transformer is securely anchored on a reinforced concrete foundation. Indoor setups require the transformer body to be perfectly aligned with the cabinet front, maintaining a seamless connection to the distribution panel, free of any gaps.
2. Installation steps:
During installation, carefully utilize designated special force points to position the transformer, incorporating anti-slip measures for enhanced safety.
Ensure the transformer's inclination remains within safe limits during transit and installation: no more than 15° along the long axis and 10° along the short axis.
Pay meticulous attention to the spacing of components during installation to prevent any tightness or looseness issues.
For terminal installations, select appropriate insulation disks based on actual conditions and ensure correct wiring.
3. Attachment installation:
When installing accessories such as gas relays, pressure relief devices, and moisture absorbers, adhere strictly to relevant standards and manufacturer guidelines for optimal performance.