Introducing our Three-Phase Oil-Immersed Distribution Transformer: a powerhouse of efficiency and reliability, built to elevate your energy systems with unmatched performance.
Product Parameters: Discover the intricate specifications that make our transformers stand out in their field, designed for excellence in every detail.
nominal
capacity
|
high
voltage side
|
High voltage
tap range
|
low
voltage side
|
Connection
group labeling
|
No-
load loss
|
Load Loss |
No-load
current
|
Short Circuit
Impedance
|
30KVA |
11KV
10.5KV
10KV
6.3KV
6KV
|
±5
±2×2.5%
|
0.4KV
0.69KV
|
Dyn11
Yyn0
|
100W |
630/600W |
2.3% |
4% |
50KVA |
130W |
910/870W |
2.0% |
4% |
63KVA |
150W |
1090/1040W |
1.9% |
4% |
80KVA |
180W |
1310/1250W |
1.9% |
4% |
100KVA |
200W |
1580/1500W |
1.8% |
4% |
125KVA |
240W |
1890/1800W |
1.7% |
4% |
160KVA |
280W |
2310/2200W |
1.6% |
4% |
200KVA |
340W |
2730/2600W |
1.5% |
4% |
250KVA |
400W |
3200/3050W |
1.4% |
4% |
315KVA |
480W |
3830/3650W |
1.4% |
4% |
400KVA |
570W |
4520/4300W |
1.3% |
4% |
500KVA |
680W |
5410/5150W |
1.2% |
4% |
630KVA |
810W |
6200W |
1.1% |
4.5% |
800KVA |
960W |
7500W |
1.0% |
4.5% |
1000KVA |
1150W |
10300W |
1.0% |
4.5% |
1250KVA |
1360W |
12000W |
0.9% |
4.5% |
1600KVA |
1640W |
14500W |
0.8% |
4.5% |
2000KVA |
1960W |
19800W |
0.8% |
5% |
2500KVA |
2310W |
23000W |
0.7% |
5% |
Oil-immersed Transformers Product Details: Delve into the comprehensive features that characterize our cutting-edge oil-immersed transformers, crafted for optimal power management.
Oil-immersed transformers, a pinnacle of engineering in power systems, are indispensable for voltage conversion and power transmission. Designed to meet high current and large capacity demands, they boast outstanding stability and reliability, making them the ideal choice for modern power grids.
Model Meaning: Unravel the significance behind our model designations, each tailored to ensure precision and clarity in identifying our transformative solutions.
Performance Characteristics: Explore the robust features that define our transformers, engineered for peak efficiency and enduring performance under the most demanding conditions.
1. Winding structure: Our high-voltage winding employs a multi-layer cylindrical design, featuring continuous or connecting continuous structures. This innovative design enhances shock distribution, minimizes magnetic leakage, and provides superior mechanical strength and resistance to short circuits.
The high-voltage winding adopts a multi-layer cylindrical structure, either continuous or connecting continuous, enhancing winding shock distribution, minimizing magnetic leakage, and ensuring high mechanical strength with strong short-circuit resistance.
2. Iron core design: Our transformers utilize premium cold-rolled grain-oriented silicon steel sheets. The full diagonal seam stacking method significantly reduces no-load loss and no-load current, optimizing efficiency.
Adoption of high-quality cold-rolled grain-oriented silicon steel sheets with a full diagonal seam stacking method drastically reduces no-load losses and no-load current, contributing to the transformer's supreme efficiency.
3. Fastening and anti-loosening: We employ advanced fastening techniques for both core and windings. Self-locking anti-loosening nuts secure high and low voltage leads, adopting a non-hanging center structure to endure transportation vibrations. All fasteners include nuts to prevent loosening over long-term operation.
The core and windings are secured with robust fastening measures, and high and low voltage leads are equipped with self-locking anti-loosening nuts, adopting a non-hanging center structure to withstand transportation vibrations. All fasteners come with locking nuts to ensure they remain secure during long-term use.
4. Vacuum processing: Our vacuum drying process for coils and cores, along with vacuum filtering and injection of transformer oil, effectively minimizes moisture within the transformer, ensuring optimal performance and longevity.
Coils and cores undergo vacuum drying, while transformer oil is meticulously vacuum filtered and injected to minimize internal moisture, ensuring exceptional performance and durability.
5. Oil tank design: The corrugated sheet oil tank features a breathing function, compensating for oil volume changes due to temperature fluctuations. It eliminates the need for an oil storage cabinet, reducing the transformer's height and enhancing its compact design.
The oil tank utilizes corrugated sheets with a breathing function, effectively compensating for oil volume changes due to temperature variations. This design eliminates the need for an oil storage cabinet, thus reducing the transformer's height and enhancing its compact design.
6. Other features: Boasting a stunning aesthetic and compact size, our transformers require minimal installation space, making them the perfect choice for maintenance-free operation.
With a beautiful appearance and compact size, our transformers occupy minimal installation space, making them the ideal maintenance-free product choice.
Our transformers are extensively utilized in power plants, substations, industrial and mining enterprises, as well as rural power grids, proving vital in diverse power distribution systems.
Environment and Requirements: Ensure your transformer operates within optimal conditions by understanding the environmental specifications and requirements.
Ambient temperature: Maintain functionality by keeping the ambient temperature between -25°C and +40°C for optimal transformer performance. The ambient temperature is generally required to be between -25°C and +40°C to maintain optimal performance of the transformer.
Altitude limit: Ensure reliability by installing transformers at altitudes not exceeding 1000m, maintaining performance integrity. For reliable performance, transformers should be installed at altitudes not exceeding 1000m.
Air humidity: Keep relative humidity below 90% at +25ºC to prevent moisture-related issues and ensure long-term operational efficiency. To prevent moisture-related issues and maintain operational efficiency, ensure air humidity does not exceed 90% relative humidity at +25ºC.
Installation place: Choose a site free from corrosive gases and significant dirt to protect the transformer and ensure longevity. Select an installation area free of corrosive gases and significant dirt to protect the transformer and ensure its longevity.
Maintenance and upkeep: Keep your transformer in peak condition with regular inspections and timely maintenance practices.
Regular inspection: Conduct frequent checks on oil levels and insulation strength. If issues arise, replace transformer oil promptly to maintain optimal functionality. Conduct frequent checks on oil levels and perform insulation strength tests. Should issues arise, promptly replace transformer oil to maintain optimal functionality.
Stable operation: Safeguard your transformer by avoiding overloads and short circuits, ensuring stable and continuous operation. To maintain stability and prevent abnormalities, such as overloads and short circuits, ensure continuous and stable operation of the transformer.
Safety attention: Prioritize safety by addressing plant ventilation and fire prevention during installation, following technical specifications for correct setup. Before installation, ensure plant ventilation and fire prevention measures are in place, following technical specifications for correct setup.
Order process: Experience a seamless ordering journey with our customer-focused process, guiding you from selection to delivery.
Factory Scene: Our state-of-the-art factory showcases advanced manufacturing processes and stringent quality control, ensuring top-tier products.
Certificates: Our transformers are backed by extensive certifications, assuring compliance with international standards and unparalleled quality.

FAQ: Your queries answered-explore our comprehensive FAQ section for insights and solutions to common questions.
1. Are you a trading company or manufacturer? Discover the expertise behind our products and services.
We are a distinguished factory with a decade of experience specializing in high and low voltage switchgears, substations, transformers, cable distribution boxes, and a variety of electrical equipment, including vacuum circuit breakers and load break switches.
Our factory proudly stands as a prestigious and excellent supplier to the State Grid Corporation of China, ensuring top-quality and reliable electrical solutions.
2. Do you accept customized service?
We offer comprehensive OEM/ODM services, with the capability to elegantly print your logo on the product. Our highly skilled technical and quotation teams are dedicated to crafting a project tailored to your specific drawings and parameters, ensuring complete satisfaction.
3. What is your MOQ?
Our minimum order quantity is as accommodating as just 1 piece, making it highly accessible for all orders.
4. How long is your delivery lead time?
Our efficient supply chain ensures adaptability to your product requirements and order quantity. Typically, our standard delivery timeframe is between 5 to 10 working days.
5. How do you solve quality problems?
To address quality concerns, kindly provide detailed photographs of the issues. Our expert technical and quality testing departments will conduct a thorough analysis, and we are committed to delivering a satisfactory solution within just 2 days.
6. What are your payment terms?
We offer flexible payment terms: 30% T/T in advance, with the remaining 70% due before shipment. Additionally, we accommodate payments through West Union and L/C.