Customization: | Available |
---|---|
Application: | Power, Instrument, Rectifier |
Phase: | Three |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
10kv/20kv/35kv 0.4 Oil-Immersed Three-Phase Transformer
The 20kV oil-immersed transformer is a state-of-the-art electrical apparatus utilizing insulating oil as the core insulating medium. This marvel of engineering is composed of a precision-crafted iron core, robust coil, efficient voltage regulating switch, and a durable oil tank. It is designed to expertly convert voltages and facilitate the seamless transmission of alternating current energy. Boasting a compact design, cost-effectiveness, and exceptional weather-resistant properties, this transformer is indispensable in power systems, industrial and mining sectors, transportation networks, postal and telecommunications departments, as well as in esteemed scientific research institutions.
nominal
capacity
|
high
voltage side
|
High voltage
tap range
|
low
voltage side
|
Connection
group labeling
|
No-
load loss
|
Load Loss |
No-load
current
|
Short Circuit
Impedance
|
30KVA |
11KV
10.5KV
10KV 6.3KV 6KV |
±5
±2×2.5%
|
0.4KV
0.69KV
|
Dyn11
Yyn0
|
100W | 630/600W | 2.3% | 4% |
50KVA | 130W | 910/870W | 2.0% | 4% | ||||
63KVA | 150W | 1090/1040W | 1.9% | 4% | ||||
80KVA | 180W | 1310/1250W | 1.9% | 4% | ||||
100KVA | 200W | 1580/1500W | 1.8% | 4% | ||||
125KVA | 240W | 1890/1800W | 1.7% | 4% | ||||
160KVA | 280W | 2310/2200W | 1.6% | 4% | ||||
200KVA | 340W | 2730/2600W | 1.5% | 4% | ||||
250KVA | 400W | 3200/3050W | 1.4% | 4% | ||||
315KVA | 480W | 3830/3650W | 1.4% | 4% | ||||
400KVA | 570W | 4520/4300W | 1.3% | 4% | ||||
500KVA | 680W | 5410/5150W | 1.2% | 4% | ||||
630KVA | 810W | 6200W | 1.1% | 4.5% | ||||
800KVA | 960W | 7500W | 1.0% | 4.5% | ||||
1000KVA | 1150W | 10300W | 1.0% | 4.5% | ||||
1250KVA | 1360W | 12000W | 0.9% | 4.5% | ||||
1600KVA | 1640W | 14500W | 0.8% | 4.5% | ||||
2000KVA | 1960W | 19800W | 0.8% | 5% | ||||
2500KVA | 2310W | 23000W | 0.7% | 5% |
Installation Instructions:
1. Installation form:
The versatile 20kV oil-immersed transformers can be installed with ease in various configurations such as pole-mounted, outdoor, or indoor setups, catering to a wide array of operational environments.
For outdoor installations, ensure it is securely mounted on a reinforced concrete foundation; whereas for indoor installations, the transformer must be precisely aligned with the cabinet front, achieving a seamless attachment to the distribution panel, free of gaps.
2. Installation steps:
During installation, utilize designated force points specifically engineered for this product, while implementing anti-slip measures to guarantee stability.
It is crucial to maintain the transformer body's inclination within strict parameters during transit and installation (not exceeding 15° longitudinally and 10° latitudinally) for optimal performance.
Carefully monitor the spacing between components, ensuring they are neither overly tight nor excessively loose, to secure efficient operation.
When setting up terminals, select appropriate insulation disks tailored to the specific scenario and ensure accurate wiring.
3. Attachment installation:
When integrating attachments such as gas relays, pressure relief devices, moisture absorbers, and sleeves, it is imperative to adhere to established standards and manufacturer guidelines to uphold safety and performance integrity.
Certificates: